SAVESEARCH ® system

Efficient insulation monitoring

Impending or existing insulation faults between coil and shunts on coreless induction furnaces can be quickly detected with the SAVESEARCH® system. Fault localization is also possible, because each shunt insulating layer is monitored separately.

Hardware components SAVESEARCH system Operator display SAVESEARCH system
Hardware components of the SAVESEARCH ® system
Left: Measuring unit
Right: External control and visualization unit
Operator display of the SAVESEARCH ® system using the example of a coreless induction furnace

Application

Application

Coreless induction furnace:

The search for insulation faults on coreless induction furnaces is difficult and time consuming because ground faults occur unpredictably for a very short time. The common ground leakage indicator allows only an indication about the overall condition of the electrical insulation between the coil and electrically grounded components. It is impossible to pinpoint where the insulation fault happens; between the grounded molten bath and coil, between coil and the shunts, between capacitor / power supply and ground. Even in the case where there is an insulation fault between coil and shunts, the question remains at which single shunt the problem exists.

Benefits

Benefits

Increase Equipment up-time
based on fast fault localization and preventive maintenance

Optimize operating costs
by reducing the costs of maintenance and production losses

Significantly improves safety
based on improved monitoring of the coreless induction furnace

Pruduct attributes

Pruduct attributes

– Simple and safe handling
– Robust equipment for working in harsh environments
– Easy integration into existing networks
– Electrically autonomous measuring system
– No impact on the existing ground leakage indicator
– Fast remote service via TeamViewer
– Trend identification based on continuously recorded data
– Easy integration into furnace controls

Functionality

Functionality

The measurement range of the SAVESEARCH® system is significantly wider than that of a common ground leakage indicator. Therefore an early detection of developing insulation faults is possible. Hence preventive maintenance and cleaning procedures can be scheduled, because the measurement trend identifies developing problems. Between coil and each shunt, one electrode is installed to replace the standard insulation. This allows quick identification of which shunt insulation is affected before an error occurs. The SAVESEARCH® system works independently. As the common ground leakage indicator is not affected, it should be used in parallel.